• New

MUST 12 kW Hybrid Inverter PH11-12KL3-EU 3-phase 48 V

Add to compare
Indeks:
PH11-12KL3-EU

The MUST PH11-12KL3-EU is a three-phase hybrid inverter with a rated power of 12 kW , designed for use with photovoltaic systems and 48V low-voltage energy storage systems. It supports on-grid and off-grid operation, unbalanced phase loading, BMS communication, and generator integration. This model offers a maximum charge/discharge current of 240 A , two MPPT trackers, Wi-Fi monitoring, and an IP66 rating.

7,495.43 zł (Tax Incl.)
6,093.85 zł (Tax Excl.)
Made to order
24-hour service
Over 20 years of experience
Up to 5 years warranty

Powiązane kategorie

7,495.43 zł (Tax Incl.)
6,093.85 zł (Tax Excl.)
7,495.43 zł (Tax Incl.)
6,093.85 zł (Tax Excl.)

Description

MUST 12 kW PH11-12KL3-EU hybrid inverter - three-phase inverter for 48 V energy storage

MUST PH11-12KL3-EU is a modern three-phase hybrid inverter with a rated power of 12,000 W , designed for the construction of advanced energy systems combining a photovoltaic installation, energy storage, power grid and, optionally, a generator.

This is the most powerful model in the MUST PH1100 EU series, utilizing a low-voltage 48V battery system. Thanks to its high power, the ability to connect PV systems up to 15.6 kWp , and a maximum charge and discharge current of 240 A , the inverter can be used in larger home installations, farms, and small and medium-sized commercial facilities.

The inverter supports both on-grid operation, i.e. in cooperation with the power grid, as well as off-grid operation, enabling the construction of a system that provides power to receivers also independently of the grid.

Cooperation with a 48 V energy storage

The PH11-12KL3-EU works with both lithium and lead-acid batteries .
The nominal voltage of the battery system is 48 V , while the battery voltage range is 40–60 V.
In the case of lithium batteries, the inverter enables communication with the BMS system, thanks to which the charging strategy can be adapted to the parameters of the cooperating energy storage device.
The maximum charge and discharge power for the PH11-12KL3-EU model is 12,000 W and the maximum charge/discharge current reaches 240 A.
Such parameters enable cooperation with larger energy storage systems and efficient transfer of high power between the battery, PV installation and receivers.

Photovoltaic installation support up to 15.6 kWp

The PH11-12KL3-EU model enables the connection of a photovoltaic installation with a maximum input power of 15,600 W.

This allows the PV system to be oversized relative to the inverter's rated power. The PH1100 EU series supports a DC/AC ratio of approximately 1.3 , allowing for increased available energy production even during periods of lower solar irradiance.
The maximum DC input voltage is 800 V , the nominal PV voltage is 550 V , and the operating range of the MPPT trackers is 200–650 V.
The inverter has 2 independent MPPT trackers , which allows for more flexible design of the photovoltaic installation, e.g. with panels mounted on different roof surfaces or operating in different sunlight conditions.
For the 12 kW model, the maximum PV input current is 30 A / 15 A and the string configuration for MPPT trackers is 2+1 .

Three-phase unbalanced output

MUST PH11-12KL3-EU supports 100% unbalanced three-phase output , so the power does not need to be evenly distributed between all three phases.

The maximum output power of a single phase can reach up to 50% of the rated power of the inverter .
This solution is particularly useful in installations where there are significant differences in the load on individual phases – for example, in a house equipped with a large number of electrical receivers, a farm, a workshop or a service facility.
In such a case, the inverter can use the energy stored in the storage and produced by the PV installation much more flexibly.

Integration with a generator

One of the most important functionalities of the PH1100 EU series is the ability to work with a power generator .
The inverter has a dedicated generator input, making it possible to build a system consisting of:

photovoltaic installation + energy storage + power grid + generator.

In a situation where energy production from PV is insufficient, the energy storage is discharged and the power grid is unavailable, the generator can be another source of power to the system.
The manufacturer has provided for this configuration directly in the inverter design and presents it in the installation diagram in the device card.

Possibility of parallel operation of up to 6 inverters

The MUST PH11-12KL3-EU inverter enables parallel operation of up to 6 devices , both in grid-connected and off-grid systems.
This makes it possible to build much larger systems and later expand the installation as energy demand increases.

The PH1100 EU series also supports:

AC coupling when modernizing an existing PV installation,
multiple batteries connected in parallel,
integration of the energy storage with the generator.

Time of Use function - intelligent use of energy

The inverter is equipped with a Time of Use function that allows you to program up to 6 time intervals for the system to operate.
This allows you to determine at what times the energy storage should be charged, when energy should be drawn from it and how the system should use the available energy sources.
This function can be particularly useful for tariffs depending on the time of day and in installations where the aim is to increase the self-consumption of energy produced from photovoltaics.

WiFi monitoring and BMS communication

PH11-12KL3-EU is equipped with extensive communication capabilities enabling the integration of the inverter with an energy storage system and an installation management system.

The inverter has:

2× CAN – communication with BMS and parallel operation,
RS485 – communication with BMS,
RS232 – remote control,
DRM port,
WiFi – monitoring system operation.

This allows you to control the operation of the inverter, energy storage and PV installation, and adapt the system's operation to the needs of a specific facility.

Why choose MUST PH11-12KL3-EU?

  • Rated power 12 kW – the most powerful variant of the PH1100 EU series.
  • Three-phase operation 380/400 V.
  • Low voltage 48V energy storage .
  • Maximum power of the PV installation is up to 15.6 kW .
  • 2 independent MPPT trackers .
  • Maximum PV input current 30 A / 15 A.
  • Maximum charge/discharge current 240 A.
  • Maximum charging/discharging power 12 kW .
  • On-grid and off-grid operation .
  • 100% unbalanced three-phase output .
  • Up to 50% of rated power on a single phase .
  • Operating a power generator .
  • Possibility of parallel operation of up to 6 inverters .
  • Support for multiple batteries connected in parallel .
  • AC coupling for retrofitting existing PV installations .
  • CAN / RS485 / RS232 .
  • WiFi monitoring .
  • Time of Use function – up to 6 time intervals .
  • IP66 protection class .
  • Maximum efficiency ≥97.6% .
  • 5-year warranty .

Application

The MUST PH11-12KL3-EU 12 kW hybrid inverter is designed primarily for larger installations that require effective management of significant amounts of energy.

It can be used, among others, in:

larger single-family homes,
buildings with large photovoltaic installations,
farms,
workshops,
small and medium-sized enterprises,
premises and service facilities,
emergency power systems,
installations cooperating with a power generator,
modernized photovoltaic installations equipped with an energy storage.

The combination of a PV installation, a hybrid inverter and an energy storage system enables increased self-consumption , storage of surplus production and use of energy during periods of highest demand.

Thanks to integration with the generator, the inverter can also be part of a more extensive system that increases the facility's energy security.

Specification

Libra
46 kg
Dimensions L x W x H
446 x 656 x 285mm
Communication
RS485/CAN
Producer
MUST
Series
PH1100 EU
Model
PH11-12KL3-EU
Product type
On/off-grid hybrid inverter
IP protection class
IP66
Certificates and standards
CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC 62109-1, EN IEC 62109-2); CE-LVD(EN 62477-1) ; IEC 60529; EN50549-1; Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021)C10/C11; UNE217001-2020; UNE217002-2020, NTS-631 (Type A); G98+G99
Charging curve
3-step adaptation with maintenance/equalization
Overcurrent protection/overheating protection
Yes / Yes
Maximum charge/discharge power
12000 W
Maximum charge/discharge current
240A
Maximum DC input power
15600W
Rated PV input voltage
550V
Maximum DC voltage
800V
Starting voltage
160V
Minimum voltage for connection to the mains
310V
DC voltage range at full load
350-650V
Enter the high voltage fault recovery point
800V
MPPT voltage range
200~650V
Maximum input current
30A/15A
Number of MPP trackers
2
Number of strings per MPP Tracker
2+1
Rated AC Input/Output Power
12000 W
Maximum AC Input/Output Power
13200 W
Rated AC input/output current
18.2/17.4A
Maximum AC Input/Output Current
20/19.1A
Maximum output current three-phase unbalanced
27.3/26.1A
Power factor adjustment range
0.8 overexcitation to 0.8 underexcitation
Nominal input/output voltage
220/380,230/400 V AC
Nominal input/output network frequency/range
50/60;45~55/55-65
Number of AC phases
Three-phase
Total Harmonic Distortion Current (THDi)
3% (of nominal power)
DC generator
0.5% ln
Battery type
Lead-acid battery / Lithium battery
Battery voltage
48V

Attachments

Reviews

Find out what our customers say about us
No customer reviews for the moment.