Stationary power generator AP 650 V-O (520 kW)
Stationary unit in open version · Volvo engine
AP 650 VO generator: power, efficiency and reliability for demanding customers
The AP 650 VO is a powerful three-phase generator with a maximum output of 650 kVA / 520 kW , designed for indoor use. The Volvo TAD1642GE diesel engine with electronic speed control ensures stable operation even in the most demanding conditions.
The AP VO series open stationary generators are installed in dedicated technical rooms or machine rooms. The open-frame design allows easy access to all components, and the design is suitable for intensive emergency or continuous operation in industrial, commercial, and public facilities.
650 kVA
maximum power ESP
900 liters
fuel tank
almost 8 hours
operation at 100% load
60 months
emergency operation warranty
Key technical parameters
| Maximum power ESP | 650 kVA / 520 kW |
| PRP rated power | 585 kVA / 468 kW |
| Rated current | 848 A |
| Generator | STRATHON ECO, brushless |
| Efficiency / degree of protection | 93% / IP 23 |
| Voltage regulator | DVR, digital |
| Driver | AMF 25 with LCD display |
| Construction | open (Open Type), for use inside buildings |
Volvo TAD1642GE engine
| Type | diesel, Volvo TAD1642GE |
| Capacity | 16.12 l |
| Speed controller | electronic |
| Tank / fuel consumption | 900 l / 114 l/h at 100% load |
What makes the AP 650 VO stand out?
01
Volvo TAD1642GE engine
A 16.12-liter diesel engine with electronic speed control. Stable operation even in the most demanding conditions.
02
Precision generator
The brushless STRATHON ECO generator with 93% efficiency and IP 23 protection class, with a digital DVR, precisely maintains voltage parameters.
03
AMF 25 controller
Automatic power switchover in the event of a mains failure. The LCD display shows voltage, current, frequency, fuel level, battery status, and energy meter. Emergency alarms and remote monitoring (with the appropriate module).
04
Long autonomy
A 900 l tank with a consumption of 114 l/h (100% load) provides almost 8 hours of operation without refueling.
Where will the AP 650 VO be used?
✓ production plants, see aggregates for industry
✓ data centers, see aggregates for data centers
✓ hospitals, see units for healthcare
✓ administration buildings and public facilities
Possibility of expansion
✓ synchronization with other units
✓ external SZR cabinet (IP54)
✓ communication system (LAN, RS485, GPRS)
✓ ventilation system of the generator room
✓ remote monitoring via the WebSupervisor application
The generator is installed in accordance with the installation guidelines: connections, foundation dimensions, and exhaust system. We describe the room requirements in the generator installation requirements section, and the generator room preparation, foundation, and commissioning are performed as part of our design and assembly service.
Guarantee
Emergency operation: 60 months (up to 1000 operating hours per year).
Continuous operation: 12 months.
Support
Full service support and technical advice are provided. Inspections and maintenance are performed by AKMEL . Detailed specifications can be found in the catalog datasheet.
AP 650 VO: a reliable and expandable energy source
A solution for investors and facility managers who need a reliable, high-efficiency energy source with the ability to easily expand the system. Contact us and we will select the right configuration for your facility.
- Execution
- Open
- Maximum power E.S.P. kVA
- 650 kVA
- Maximum power E.S.P. kW
- 520 kW
- Rated power P.R.P. kVA
- 585 kVA
- Rated power P.R.P. kW
- 468 kW
- Rated current
- 848 A
- Voltage
- 400V
- Frequency
- 50 Hz
- Engine
- Volvo
- Fuel type
- Diesel
- Exhaust emissions
- Non-Emission
- Fuel consumption 100% l/h
- 114 l/h
- Fuel tank
- 900 liters
- Dimensions L x W x H
- 4000*1460*2610