AP 1870 P three-phase generator – reliable power for the largest facilities
What is the AP 1870 P generator?
The AP 1870 P is one of the most powerful three-phase generators in our range – with a maximum output of 1870 kVA / 1496 kW , designed for standby or continuous power in large industrial plants, data centers, hospitals, and strategic investments. Equipped with a reliable Perkins 4012-46TAG3A engine, it meets the emissions requirements of Directive 97/68/EC.
What are the key technical parameters of the AP 1870 P generator?
-
ESP maximum power: 1870 kVA / 1496 kW
-
PRP rated power: 1683 kVA / 1346 kW
-
Rated current: 2440 A
-
Nominal voltage: 400 V
-
Frequency: 50 Hz
-
Generator: STRATHON ECO 1900 KW, brushless, synchronous
-
Generator efficiency: 93%
-
Protection class: IP 23
-
Insulation class: H
Why choose the AP 1870 P generator?
What makes the AP 1870 P unique?
✅ Perkins 4012-46TAG3A engine: 12-cylinder V-twin, capacity 45.84 l, power 1643 kW, with electronic speed controller – guarantee of stable parameters even at maximum load.
✅ Modern AMF 20 controller: Automatic start-up, current and voltage measurement in 3 phases, event log (up to 119 items), energy meter and full online monitoring (GSM, LAN, Modbus).
✅ Large fuel tank: Capacity 2000 l , with fuel consumption 275 l/h at full load - long operating time without refueling.
✅ Quiet operation: Soundproof housing – noise level only 70 dB(A) at a distance of 7 m, despite high power.
Where is the AP 1870 P generator best suited?
AP 1870 P is a reliable energy source for:
-
large industrial plants and production halls,
-
data centers and healthcare facilities,
-
construction and infrastructure investments,
-
renewable energy farms and facilities where constant, high power and compliance with emission standards are required.
What additional options does the AP 1870 P unit offer?
You can expand the unit with:
-
external fuel tank,
-
synchronization with other units,
-
ventilation and exhaust system,
-
spark arrester,
-
differential protection,
-
remote monitoring (GSM, LAN),
-
execution in a different voltage configuration,
-
external SZR cabinet (IP54),
-
foundation slab.
What is the service and operation of AP 1870 P generators like?
How to take care of the generator?
? Oil and filter change: after the first 100 hours, then every 500 hours or every year.
? Coolant: replace every 1000 hours or every 2 years.
? AMF 20 Controller: enables remote monitoring, SMS/email notifications, viewing via InteliMonitor and WebSupervisor.
What are the warranty conditions for the AP 1870 P?
-
Reserve mode: 60 months (or 1000 operating hours) – provided inspections are performed.
-
Continuous operation mode: 12 months (or 1000 operating hours).
Choose the highest power and reliability with the AP 1870 P
AP 1870 P is a reliable power supply for strategic facilities – high power, modern control and quiet operation.
Contact us and request an offer tailored to your needs!
- Execution
- Built-up
- Maximum power ESP kVA
- 1870 kVA
- Maximum power ESP kW
- 1496 kW
- Rated power PRP kVA
- 1683 kVA
- Rated power PRP kW
- 1346 kW
- Rated current
- 2440 A
- Tension
- 400V
- Engine
- Perkins
- Fuel type
- Diesel
- Fuel consumption 100% l/h
- 275 l/h
- Fuel tank
- 2000 l
- Dimensions L x W x H
- 8000 x 3000 x 3300 mm
- Application
-
Business
Data Center
Health service
Industry