FD 300 SF three-phase generator – Scania power for medium and heavy loads
What is the FD 300 SF generator?
The FD 300 SF is a reliable three-phase generator with a maximum output of 330 kVA / 264 kW , designed for emergency or continuous operation in medium- and large-scale industrial plants, logistics centers, hospitals, renewable energy farms, and infrastructure facilities. Equipped with a Scania DC09 072A 02-13 engine, it complies with the 97/68/EC exhaust emissions directive.
What are the key technical parameters of the FD 300 SF generator?
-
ESP maximum power: 330 kVA / 264 kW
-
PRP rated power: 300 kVA / 240 kW
-
Rated current: 433 A
-
Nominal voltage: 400 V
-
Frequency: 50 Hz
-
Generator: Leroy Somer, brushless, synchronous
-
AVR Type: Digital
-
Protection class: IP 23
-
Insulation class: H
-
Reactance Xd: 11.8%
-
Voltage stabilization: ±0.25%
Why choose the FD 300 SF generator?
What makes the FD 300 SF stand out?
✅ Scania DC09 072A 02-13 engine: 5-cylinder in-line, capacity 9.3 l, power 261 kW, electronic speed governor – guarantees stable operation even under heavy loads.
✅ AMF 25 controller: Intuitive graphical interface, automatic start, current and voltage measurement in 3 phases, event log (up to 119 entries), energy meter, online monitoring (GSM, LAN, Modbus).
✅ Economical combustion: Fuel consumption at 100% load is only 61.7 l/h , and the 999 l fuel tank ensures many hours of uninterrupted operation.
✅ Solid construction: weight approx. 2730 kg, dimensions of the open version: 2967 x 1564 x 2110 mm, foundation plate: 3367 x 1964 mm.
✅ Quiet operation: sound pressure level of ~95.1 dB(A) at a distance of 7 m.
Where is the FD 300 SF power generator best suited?
The FD 300 SF is a reliable energy source for:
-
medium and large industrial plants,
-
logistics centers and warehouses,
-
renewable energy farms and critical infrastructure,
-
hospitals and health care facilities,
-
places where continuous power supply is required.
What additional options does the FD 300 SF unit offer?
You can expand the unit with:
-
external fuel tank,
-
synchronization with other units,
-
ventilation and exhaust system,
-
spark arrester,
-
differential protection,
-
remote monitoring (GSM, LAN, Modbus),
-
execution in a different voltage configuration,
-
external SZR cabinet (IP54),
-
foundation slab.
What is the service and operation of FD 300 SF generators like?
How to take care of the generator?
? Oil and filter change: after the first 100 hours of operation, then every 500 hours or every year (oil pan capacity: 36 l).
? Coolant: replace every 1000 hours or every 2 years (capacity: 37 l).
? AMF 25 Controller: enables online monitoring, SMS/email notifications, InteliMonitor and WebSupervisor.
What are the warranty terms for the FD 300 SF?
-
Reserve mode: 60 months (or 1000 operating hours), provided periodic inspections are performed.
-
Continuous operation mode: 12 months (or 1000 operating hours).
Choose reliable power with the FD 300 SF
The FD 300 SF offers solid power, safety and compliance with emission standards – wherever electricity must be available at all times.
Contact us and request an offer tailored to your needs!
- Execution
- Open
- Maximum power ESP kVA
- 330 kVA
- Maximum power ESP kW
- 264 kW
- Rated power PRP kVA
- 300 kVA
- Rated power PRP kW
- 240 kW
- Rated current
- 433 A
- Tension
- 400V
- Frequency
- 50 Hz
- Engine
- Scania
- Fuel type
- Diesel
- Fuel consumption 100% l/h
- 61.7 l/h
- Fuel tank
- 999 l
- Dimensions L x W x H
- 2967 x 1564 x 2110 mm
- Application
-
Business
Construction
Data Center
Health service
Industry - Weight
- 2730 kg